60%

ABB AF580-30-11 100-250V 50/60Hz / 100-250V DC Contactor

Share On:

Original price was: $880.00.Current price is: $528.00.

Meta:
Seller Notes : “Excellent Condition!!”
Brand : ABB

AF580-30-11-70 General Information Extended Product Type: AF580-30-11-70 Product ID: 1SFL617001R7011 EAN: 7320500217696 Catalog Description: AF580-30-11 100-250V 50/60Hz / 100-250V DC Contactor Long Description: The AF580-30-11-70 is a 3 pole – 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 315 kW / 400 V AC (AC-3) or 500 hp / 480 V UL and switching power circuits up to 800 A (AC-1) or 750 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories. Dimensions Product Net Width: 210 mm Product Net Depth / Length: 242 mm Product Net Height: 283 mm Product Net Weight: 13.6 kg Technical Number of Main Contacts NO: 3 Number of Main Contacts NC: 0 Number of Auxiliary Contacts NO: 1 Number of Auxiliary Contacts NC: 1 Rated Operational Voltage: Main Circuit 1000 V Rated Frequency (f): Main Circuit 50 / 60 Hz Conventional Free-air Thermal Current (I th ): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 800 A Rated Operational Current AC-1 (I e ): (1000 V) 40 °C 800 A (1000 V) 55 °C 700 A (1000 V) 70 °C 580 A (690 V) 40 °C 800 A (690 V) 55 °C 700 A (690 V) 70 °C 580 A Rated Operational Current AC-3 (I e ): (415 V) 55 °C 580 A (440 V) 55 °C 580 A (500 V) 55 °C 580 A (690 V) 55 °C 500 A (1000 V) 55 °C 250 A (380 / 400 V) 55 °C 580 A (220 / 230 / 240 V) 55 °C 580 Rated Operational Power AC-3 (P e ): (415 V) 355 kW (440 V) 355 kW (500 V) 400 kW (690 V) 500 kW (1000 V) 355 kW (380 / 400 V) 315 kW (220 / 230 / 240 V) 160 kW Rated Breaking Capacity AC-3: 8 x Ie AC-3 Rated Making Capacity AC-3: 10 x Ie AC-3 Short-Circuit Protective Devices: gG Type Fuses 1000 A Rated Short-time Withstand Current Low Voltage (I cw ): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 6400 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3500 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 7000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 4500 A Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 6000 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 5000 A Maximum Electrical Switching Frequency: (AC-1) 300 cycles per hour (AC-2 / AC-4) 60 cycles per hour (AC-3) 300 cycles per hour Rated Operational Current DC-1 (I e ): (110 V) 1-Pole, 40 °C 800 A (110 V) 2 Poles in Series, 40 °C 800 A (220 V) 3 Poles in Series, 40 °C 800 A (600 V) 3 Poles in Series, 40 °C 800 A (850 V) 3 Poles in Series, 40 °C 800 A Rated Operational Current DC-3 (I e ): (110 V) 1-Pole, 40 °C 800 A (110 V) 2 Poles in Series, 40 °C 800 A (220 V) 3 Poles in Series, 40 °C 800 A (600 V) 3 Poles in Series, 40 °C 800 A Rated Operational Current DC-5 (I e ): (110 V) 1-Pole, 40 °C 800 A (110 V) 2 Poles in Series, 40 °C 800 A (220 V) 3 Poles in Series, 40 °C 800 A (600 V) 3 Poles in Series, 40 °C 800 A Rated Insulation Voltage (U i ): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V Rated Impulse Withstand Voltage (U imp ): Main Circuit 8 kV Mechanical Durability: 3 million Maximum Mechanical Switching Frequency: 300 cycles per hour Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. … 1.1 x Uc Max. (at θ ≤ 70 °C) Rated Control Circuit Voltage (U c ): 50 Hz 100 … 250 V 60 Hz 100 … 250 V DC Operation 100 … 250 V Coil Consumption: Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A Holding at Max. Rated Control Circuit Voltage DC 5 V·A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 880 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 880 V·A Pull-in at Max. Rated Control Circuit Voltage DC 880 V·A Operate Time: Between Coil De-energization and NC Contact Closing 50 … 70 ms Between Coil De-energization and NO Contact Opening 53 … 73 ms Between Coil Energization and NC Contact Opening 45 … 115 ms Between Coil Energization and NO Contact Closing 50 … 120 ms Connecting Capacity Main Circuit: Bar 52 mm² Rigid Al-Cable 300 mm² Rigid Cu-Cable 300 mm² Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 2x 0.75 … 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 … 2.5 mm² Flexible 2×0.75 … 2.5 mm² Solid 2 x 1 … 4 mm² Stranded 1 x 1 …. 4 mm² Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 Terminal Type: Main Circuit: Bars Technical UL/CSA Maximum Operating Voltage UL/CSA: Main Circuit 1000 V General Use Rating UL/CSA: (600 V AC) 750 A Horsepower Rating UL/CSA: (200 V AC) Three Phase 200 hp (208 V AC) Three Phase 200 hp (220 … 240 V AC) Three Phase 250 hp (440 … 480 V AC) Three Phase 500 hp (550 … 600 V AC) Three Phase 600 hp Environmental Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 … 1.1 Uc) -25 … 50 °C Close to Contactor without Thermal O/L Relay (0.85 … 1.1 Uc) -40 … 70 °C Close to Contactor for Storage -40 … +70 °C Maximum Operating Altitude Permissible: Without Derating 3000 m Resistance to Shock acc. to IEC 60068-2-27: Shock Direction: A 5 g Shock Direction: B1 5 g Shock Direction: B2 5 g Shock Direction: C1 5 g Shock Direction: C2 5 g RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 Attention Sellers – Get Templates Image Hosting, Scheduling at Auctiva.com. Track Page Views With Auctiva’s Counter